Scadify · Industrial edge controller and local automation platform

Bring reliable measurement, automation and local operations to the field.

Scadify connects field equipment with protocol integration, local SCADA, alarms, historian and resilient offline automation.

Scadify industrial edge controller with modular field I/O and communication interfaces
Conceptual industrial design render; use a released hardware photograph after engineering approval.

What it solves

Remote sites need central visibility, but local acquisition, alarms, runtime and approved control should not depend entirely on a permanent central connection.

Local acquisition

Connect meters, sensors, analyzers, actuators and equipment through a canonical tag and device model.

Edge automation

Run approved cyclic logic, command routing, runtime health and local recovery close to the process.

Local SCADA/HMI

Expose live tags, equipment status, alarms, trends and authorized actions at the site.

Historian and evidence

Retain selected measurements, events, alarms, deployments and user actions locally.

Protocol boundaries

Keep drivers separate from business logic so project-qualified protocol roles remain controlled.

Governed deployment

Use versioned automation/configuration artifacts, activation history and rollback concepts.

How it works

A traceable path from signal to operational action.

01

Bind

Map physical signals and protocols to canonical tags, devices, units, permissions and quality.

02

Run

Execute the local runtime, evaluate alarms and apply approved non-safety automation.

03

Record

Store measurements, runtime status, commands, events and deployment evidence locally.

04

Synchronize

Exchange normalized telemetry and configuration with central Enlogy products when connectivity is available.

05

Govern

Control engineering changes through roles, approval, version history and rollback.

Use cases

Built around the operating context.

The right product configuration depends on equipment, data quality, control responsibility, operating policy and the evidence required by the project.

  • Renewable plant telemetry and local SCADA
  • PPC field infrastructure
  • Factory energy and process integration
  • Retail HVAC and lighting control
  • Pumping and water infrastructure
  • Brownfield protocol modernization

Integration model

Connect the systems you already operate.

Modbus TCP and Modbus RTU/RS-485MQTTIEC 60870-5-104Meters, analyzers and invertersPLC, RTU and BMSOPC UA, BACnet/IP, DLMS/COSEM and IEC 61850 only according to release matrix

Governance and boundaries

Scadify is intended for non-safety and project-qualified automation unless a separately validated safety architecture exists. Security level, protocol roles, hardware availability and certifications must follow the current engineering release matrix.

Architecture and evidence

Make the operating model visible.

Scadify layers from local HMI and runtime to protocols, hardware and field equipment
Scadify layers from local HMI and runtime to protocols, hardware and field equipment
Scadify Structured Text automation validated, deployed, activated and rolled back
Scadify Structured Text automation validated, deployed, activated and rolled back
Scadify local-first operation with store and forward during central communication loss
Scadify local-first operation with store and forward during central communication loss

Plan your deployment

Find a solar production loss before dispatching a team

Example operating scenario

One inverter produces less than its neighbours. Compare string currents, irradiance, equipment state and meter readings to distinguish a local fault from cloud cover or a communication gap.

Data to prepare

Inverter and string inventory, meter map, weather sensors, single-line diagram, alarm history and available communication interfaces.

What Enlogy provides

A shared equipment view, contextual alarms and time-series evidence help the operator identify the affected circuit and prepare a maintenance task.

Questions to ask before buying

  • Can the demonstration distinguish missing data from zero production?
  • Which inverter brands, signals and local operating functions are included?
  • How are alarm delivery, historical retention and commissioning tested?

Illustrative workflow; project scope and acceptance criteria are agreed for your facility.

Standards compliance for this capability

Standards compliance for this capability

Enlogy provides full compliance with the standards below across development, integration and system operation and management.

IEC 61850 and grid interoperability

IEC 60870-5-104 (IEC-104) · IEC 61850 · IEC 61850-7-420 · IEC 61850-7-410 · CIM (IEC 61970 / IEC 61968)

Why you need it

Utilities and plant operators need consistent equipment meaning across SCADA, substations and dispatch systems.

What Enlogy provides

Enlogy connects telecontrol and equipment data models with a common asset context, preserving measurement quality, timestamps and command responsibility.

Explore this capability: IEC 61850 and grid interoperability

Industrial control and functional safety

IEC 61131-3 · IEC 61511 · IEC TS 63074

Why you need it

Plants need maintainable control logic and clear separation between operational control and safety functions.

What Enlogy provides

Enlogy develops PLC integration and control workflows with safety-system interfaces, interlock context and security requirements for safety-related control systems.

IEC 62443 OT cybersecurity

IEC 62443 · IEC 62351 · ISO/IEC 27001 · ISO/IEC 27002 · ISO/IEC 27019 · NIST SP 800-82 · NIST CSF 2.0

Why you need it

Connected energy systems need controlled access, secure communication and a manageable cyber-risk lifecycle.

What Enlogy provides

Enlogy applies industrial and energy-sector security across development, identity, OT interfaces, communication, monitoring and incident workflows.

Explore this capability: IEC 62443 OT cybersecurity

FAQ

Questions engineers and operators ask first.

Is Scadify a gateway or a PLC?

It combines gateway, local SCADA, historian and automation-runtime capabilities; its exact role depends on hardware, protocol and application configuration.

Can it operate without EnergyPortal?

The architecture is local-first. Essential local functions are intended to continue subject to the deployed release and configuration.

Is Scadify IEC 62443 certified?

No certification is claimed. The architecture includes a requirements-mapping and hardening path toward industrial component-security areas.

Next step

Discuss how Scadify fits your operating model.

Start a project discussion →

We use necessary storage to remember your choice. With your permission, Google Analytics measures visits and interactions; advertising options allow Google advertising measurement and optional personalised advertising. You can reject optional cookies and keep using the site.

Your choice is stored in this browser for up to 180 days. Change it at any time using Cookie preferences. Contact info@enlogy.com with privacy questions.

Read the cookie policyRead the privacy policy